QUESTION:my gas furnace has not been starting when i've turned up the termostat: i turn the temp up a few degrees above the current temp, the furnace
turns on, and the "whoosh" doesn't kick in, so the furnace (fan?)
clicks off a minute or two later. earlier the "whoosh" did start and the furnance started warming up and
moving air, but clicked off about five minutes later. i've reset the breaker, and thermostat. this problem is on and off,
worked fine on sunday, but didn't work saturday and today. my furnace does not have pilot light, says it "automatically ignites" i had a cleaning last year, so i'm due for another one and was planning
to call my local company, but just curious what to expect, or if it's
something simple i could reset i've also googled "furnace, whoosh", and seen some previous answers
about cold air from vent blowing out pilot thanks very much in advance!! i'm in colorado and it's mild temps
right now, but want to solve problem before it gets cold again.
ANSWER: It sounds like your 'Flame Sensor' is not working. It sits in the flame
of the burner and sends a small electrical current that tells the furnace
computer that there is indeed a flame there. If it's defective or covered
with crud, it won't send the proper signal and the computer will think the
burner didn't ignite and shuts the gas off for safety reasons. On my Lennox furnace, the part is a no brainer to replace.....two screws
hold it in, it costs about $15 for the part. But if you call a
repairman, you're looking at over $100, I'll guarantee! My furnace
was doing the exact same thing as yours and I got by with just cleaning the
oxidation/crud off of it. Since it's an intermittent problem, I'll bet
that's it!
|
|
|
|